White-Rodgers 50T35-743 Replacement Part
1 available at this price.
Includes:
- (1) - Universal Integrated Furnace Control Board (50T35-743)
- (1) - Installation Instructions (37-6533C)
Specifications
- Input Voltage: 25 VAC @ 60 Hz
- Max Input Current: 0.5 amp + MV Load
- Relay Load Rating (Valve): 1.5 Amp @ 24 VAC, 60 Hz 0.6 pf
- Relay Load Rating (Ignitor): 5.0 Amp @ 120 VAC, 60 Hz (Resistive)
- Relay Load Rating (Circulator): 11 FLA; 26.0 LRA @ 120 VAC
- Minimum Current to Ensure Flame Detection: 1 a DC
- Maximum Current For Non-Detection: 0.1 1 a DC
- Maximum Allowable Leakage Resistance: 100M Ohms
- Operating Temperature Range: -40° to 175°F (-40° to 80°C)
- Humidity Range: 5% to 93 % Relative (Non-Condensing)
- Flame Establishing Time: 0.8 Seconds Max
- Flame Failure Response Time: 2.0 Seconds Max
- Approved for Natural and LP Gases
- Fuse: 3 Amps
- Dimensions (LxW): 5 7/8" x 4 3/8"
Note: For Use with Hot Surface Silicon Carbide Ignitors
Replaces Old White-Rodgers Part Numbers
- 50T35-730
Other Part Numbers
White-Rodgers, 50T35-743, Integrated Furnace Control, B18099-13, Emerson Climate Technologies, 5001-8609, L45-392, E1
Fits Models:
(Press ctrl + F to find model number below.)
Goodman (B1809906, B1809908, B1809910, B189913, B1809913S), UTEC (1012-933D), Texas Instruments (41F-5), Trane (CNT04664), White Rodgers (50T35-730)
- SKU:
- 50T35-743
- Condition:
- New
- Weight:
- 2.00 LBS
- Shipping:
- Calculated at Checkout
- Voltage:
- 25