Schimpke DK190-V/5TK Replacement Part
This item must ship via freight. Please call us at 734-326-3900 to get a shipping quote.
Includes:
- (1) - Coolant Chiller (DK190-V/5TK)
Specifications
- Similar to com. No. 215440300, for cooling of water/Glycol (min. 20%)
- Heat output: air-cooled, axial fan
- Design: For non-polluted media!
- Cooling Capacity: 18.920 kcal/h = 22.000 Watt
- TK1: Water milling spindle
- TK2: Oil transmission
- TK3: Water servo motor X, Y, Z axis
- TK4: Water electrical cabinets
- TK5: Water servomotor B, C axis
- Refrigerant: R134a (Freon free)
- Cooling Medium Temp.: +15C (min.)/+35C(max.)
- Capacity Reference Point: +25C(ambient temperature)
- Operation Range: +10C to max. +35C (ambient temperature)
- Crankcase Heater: 380-480V AC, 0,07kW
- Operating Voltage: 480V +5/-10%, 60Hz, 3Ph
- Control Voltage: 24V, DC/6A (will be provided)
- Control Voltage Valves: 24V, AC
- Pipe Connections:
- TK1: 2x ESV 22
- TK2: 2x ESV 28
- TK3: 2x ESV 35
- TK4: 2x ESV 22
- TK5: 2x ESV 15
- Eplan - Fluid schema: 215.0300
- Drawing number: 8010812
- Speed Controller for Fan Drive between 30%-100%
- Remove air filter element only for air cooled condenser inclusive protection
- grid.
- Resistance capacitor for all inductive components in the cooling unit.
- Varnishing RAL 7032 structure paint.
- Three-way mixing valve in TK1-TK3-TK5 for tempering of milling spindle and
- servo motors.
- Centrifugal pump as sidestream and supply pump in TK2 and TK4 volume flow
- approx.. 140 I/min against max. 5.3 bar motor 0.74kW, 480V, 60Hz, 3Ph
- Centrifugal pump TK1 Volume flow approx. 12 I/min against max. 5.3 bar motor
- 0.74 kW, 480V, 60Hz, 3Ph
- Centrifugal pump TK3 Volume flow approx. 40 I/min against max. 5.4 bar motor
- 1.04 kW, 480V, 60Hz, 3Ph, IE-3
- Centrifugal pump TK5 Volume flow approx. 8 I/min against max. 5.3 bar motor
- 0.74kW, 480V, 60Hz, 3 PH
- Differential controller Sidestream
- Consisting a controller with digital temperature display.
- Supply Voltage: 24V, DC
- Adjustment Range: +-10.0K
- Display Range: 0-99.9C
- Set: +-0.0K
- Temperature Sensor
- PT 100, installed in the inlet of cooling system.
- Differential controller TK1, TK3, TK5
- Consisting a controller with digital temperature display
- Supply Voltage: 24V, DC
- Adjustment Range: +-10.0K
- Display Range: 0-99.9 C
- Lead temperature sensor (90.294F32-3Ma)
- PT100, inclusive approx. 20m cable
- Temperature sensor TK1
- PT100, for external mounting on the oil side, loose delivery.
- Temperature sensor TK3/TK5
- PT100, integrated in the outlet of TK3/TK5 in the cooling system.
- Installation of following parts for the closed system.
- 1 piece diaphragm type expansion tank
- 1 piece relief valve G1/2"
- 1 piece quick air relief valve
- 1 piece ball valve as filling up place
- 1 piece ball valve as breather
- 2 piece of manometers 0-10 bar/psi
- 1 piece mix tank
- 1 piece volume flow indicator
Replaces Old Schimpke Part Numbers
- There are no older part numbers.
Other Part Numbers
Schimpke, coolant chiller
Fits Models:
(Press ctrl + F to find model number below.)
Various. (Call 734-326-3900 with your model and serial number for more information.)