Skip to main content

Have Questions? Ask a Tech!

  • Genuine OEM Parts

    Offering genuine parts for your specific brand.

  • In-House HVAC Techs

    We help you diagnose, find, and install the part.

  • 1-Year Warranty & Returns

    Failed, or didn't need it? No hassle returns.

  • Expedited Delivery

    Offering competitively-priced expedited shipping.

Carrier RMOD46AE244 ECM 2.3 Motor Module

(No reviews yet) Write a Review

Call for price.

Brand
Carrier
SKU:
RMOD46AE244
Condition:
New
Weight:
5.00 LBS
Replaced by Part #:
HK46ER265

Technical Hot & Cold BBB Business Review
Brand
Carrier
SKU:
RMOD46AE244
Condition:
New
Weight:
5.00 LBS
Replaced by Part #:
HK46ER265

Have Questions? Ask a Tech!

  • Genuine OEM Parts

    Offering genuine parts for your specific brand.

  • In-House HVAC Techs

    We help you diagnose, find, and install the part.

  • 1-Year Warranty & Returns

    Failed, or didn't need it? No hassle returns.

  • Expedited Delivery

    Offering competitively-priced expedited shipping.

Carrier RMOD46AE244 Replacement Part

NOTE: THIS PART IS NO LONGER AVAILABLE. IT HAS BEEN REPLACED BY PART # HK46ER265

Includes:

  • (1) - ECM 2.3 Motor Module
  • (2) - 111A522AAP73 - 1/2" with 1/4" Hex Bolts
  • (1) - Plastic Locator Pin - A-8794728AYP1
  • (1) - Wire Tie - HY76TB121
  • (1) - Instruction Manual - 1-11K333B-60-1

Specifications

  • ECM 2.3
  • Horsepower Rating: 3/4/0.75
  • Voltage: 120/240
  • Amperage: 6.8
  • Phase: 1
  • Frequency: 60
  • Rotation: Counter Clockwise

Note: Always check the blower wheel on your blower assembly. Bad or unbalanced blower wheels can cause premature motor failure due to vibration. If you are not sure what blower wheel fits your blower assembly, call us at 734-326-3900.

🚀 Note: The most common cause of ECM motor failure is poorly conditioned power. To protect sensitive ECM modules against transient voltage, power surges, lightning, and voltage spikes, it is highly recommended that you install a Zebra VZPRO inline ECM protector.

Replaces Old Carrier Part Numbers

  • RMOD46AE243

Other Part Numbers

RMOD46AE244 Motor Control Module Variable speed motor control module for Replacement obsolete # RMOD46AE243. Use only with Carrier-BDP motor #HD46AE243. BDP, Carrier,motor: Furnace Blower: Modulating.

Fits Carrier, Bryant, Payne Models:

(Press ctrl + F to find model number below.)

40FKA006---300--, 40FKA006---310--, 40FKB006---300--, FK4ANF006000AAAA, FK4BNB006000AAAA, FK4BNB006008AAAA, FK4BNB006010AAAA, FK4BNB006015AAAA, FK4BNB006020AAAA, FK4CNB006000AAAA, FK4CNB006000AEAA, FK4CNB006000AFAA, FK4CNB006000AGAA, FK4CNB006000AHAA, FK4DNB006000AAAA, FV4ANB006000AAAA, FV4ANB006000ABAA, FV4ANB006000ACAA, FV4ANB006000ADAA, FV4BNB006000AAAA, FV4BNB006T00AAAA, PF1MNA071000AAAA, PF1MNA071000ABAA, PF1MNA071000ACAA, PF1MNA071000ADAA, PF1MNB071000AAAA

SKU:
RMOD46AE244
Condition:
New
Weight:
5.00 LBS
Replaced by Part #:
HK46ER265

Technical Hot & Cold honors all manufacturer warranties and offers a 1-year warranty on non-maintenance items.