Apiste PCU-SL14000 Replacement Part
This item must ship via freight. Please call us at 734-326-3900 to get a shipping quote.
Includes:
- (1) - Air-Cooled Chiller (PCU-SL14000)
Specifications
- Cooling scheme: Air-cooling type
- Cooling capacity (W): 13300
- Thermal capacity (W): 2500
- Circulated water: Pure water (over 1 s/cm), distilled water, pure water, ethylene glycol (less than 30% density)
- Temperature control accuracy (°C): ±0.1
- Circulated water temperature range (fresh water) (°C): 5 to 45
- Circulated water temperature range (antifreeze) (°C): -5 to 45
- Circulated water flow-rate range (L/min): 20 to 70
- Circulated water pressure range (Mpa): 0.7 or less
- Ambient temperature (°C): -5 to 45
- Type: R-410A
- Filling amount (g): 1700
- Exterior dimensions (w/o casters) (mm): H1496 x W850 x D750
- Paint color: DIC G-260 (Munsell value: N7.5 equivalent)
- Weight (kg): 145
- Power voltage (V): 3-phase AC200 to 230VAC
- Power consumption (kW): 5.7
- Current consumption (A): 17
- Breaker capacity (A): 30
- Power source capacity (kVA): 7.6
- Constituent equipment/Compressor: Shutting tightly Roundabout system
- Constituent equipment/Condenser: Parallel flow condenser type, forced air cooling system
- Constituent equipment/Cooler: Plate-type heat exchanger
- Constituent equipment/Water pump: Multistep spiral dipping mandrel
- Constituent equipment/Lift (m): 51
- Constituent equipment/Tank capacity (L): 35
- Constituent equipment/Coolant: R-410A
- Safety circuitry/Compressor: Motor protector
- Safety circuitry/Cooling cycle: Pressure switch
- Safety circuitry/Circulated water circuit: Water pressure sensor, low-water float switch
- Alarm output: No voltage open-contact (AC250V/2A)
- Water temperature upper-limit alarm output: No voltage open-contact (AC250V/2A)
- Water temperature lower-limit alarm output: No voltage open-contact (AC250V/2A)
- Operation stop output: No voltage open-contact (AC250V/2A)
- Pump output: No voltage open-contact (AC250V/2A)
- Operation stop input: No voltage input
- Error reset input: No voltage input
- Emergency stop input: No voltage input
- Ethernet (Communication standard): Ethernet 10BASE-T/100BASE-TX
- Ethernet (Communication protocol): Socket (TCP/IP), MC protocol (UDP/IP)
- Ethernet (IP address): IPv4
- LCD (Settings menu): Operation mode/Circulated water temperature alarm/Timer/Settings/Custom settings/Input-output settings/Communication settings/Error history
- LCD (Circulated water temperature movement): Circulated water temperature rising/decreasing/stable trend
- LCD (Graphical display): Internal temperature graph, circulated water pressure graph
- LCD (Input/output monitor): Input 1 (3-point)/Output 1 (3-point)/Output 2 (2-point)
- LCD (Operation monitor): Compressor high-pressure/Compressor low-pressure/Circulated water pressure/Circulated water temperature/Compressor outlet temperature/Compressor inlet temperature/Circulated water flow-rate/Circulated water temperature/Compressor operation time/Fan operation time/Pump operation time
- Water resistance: IPx4 equivalent
- Vibration resistance: MIL-STD-810F equivalent
- Safety standard: CE (low-voltage command, EMC command)
- Operation noise level (dB): 73
Replaces Old Apiste Part Numbers
- There are no older part numbers.
Fits Models:
(Press ctrl + F to find model number below.)
Various. (Call 734-326-3900 with your model and serial number for more information.)